Two-step centWave peak detection considering also isotopes
Source:R/DataClasses.R, R/functions-Params.R, R/methods-OnDiskMSnExp.R
findChromPeaks-centWaveWithPredIsoROIs.RdThis method performs a two-step centWave-based chromatographic peak detection: in a first centWave run peaks are identified for which then the location of their potential isotopes in the mz-retention time is predicted. A second centWave run is then performed on these regions of interest (ROIs). The final list of chromatographic peaks comprises all non-overlapping peaks from both centWave runs.
The findChromPeaks,OnDiskMSnExp,CentWavePredIsoParam()
method performs a two-step centWave-based chromatographic peak detection
on all samples from an OnDiskMSnExp object.
OnDiskMSnExp objects encapsule all experiment
specific data and load the spectra data (mz and intensity values) on the
fly from the original files applying also all eventual data
manipulations.
Usage
CentWavePredIsoParam(
ppm = 25,
peakwidth = c(20, 50),
snthresh = 10,
prefilter = c(3, 100),
mzCenterFun = "wMean",
integrate = 1L,
mzdiff = -0.001,
fitgauss = FALSE,
noise = 0,
verboseColumns = FALSE,
roiList = list(),
firstBaselineCheck = TRUE,
roiScales = numeric(),
extendLengthMSW = FALSE,
verboseBetaColumns = FALSE,
snthreshIsoROIs = 6.25,
maxCharge = 3,
maxIso = 5,
mzIntervalExtension = TRUE,
polarity = "unknown"
)
# S4 method for class 'OnDiskMSnExp,CentWavePredIsoParam'
findChromPeaks(
object,
param,
BPPARAM = bpparam(),
return.type = "XCMSnExp",
msLevel = 1L,
...
)Arguments
- ppm
numeric(1)defining the maximal tolerated m/z deviation in consecutive scans in parts per million (ppm) for the initial ROI definition.- peakwidth
numeric(2)with the expected approximate peak width in chromatographic space. Given as a range (min, max) in seconds.- snthresh
numeric(1)defining the signal to noise ratio cutoff.- prefilter
numeric(2):c(k, I)specifying the prefilter step for the first analysis step (ROI detection). Mass traces are only retained if they contain at leastkpeaks with intensity>= I.- mzCenterFun
Name of the function to calculate the m/z center of the chromatographic peak. Allowed are:
"wMean": intensity weighted mean of the peak's m/z values,"mean": mean of the peak's m/z values,"apex": use the m/z value at the peak apex,"wMeanApex3": intensity weighted mean of the m/z value at the peak apex and the m/z values left and right of it and"meanApex3": mean of the m/z value of the peak apex and the m/z values left and right of it.- integrate
Integration method. For
integrate = 1peak limits are found through descent on the mexican hat filtered data, forintegrate = 2the descent is done on the real data. The latter method is more accurate but prone to noise, while the former is more robust, but less exact.- mzdiff
numeric(1)representing the minimum difference in m/z dimension required for peaks with overlapping retention times; can be negative to allow overlap. During peak post-processing, peaks defined to be overlapping are reduced to the one peak with the largest signal.- fitgauss
logical(1)whether or not a Gaussian should be fitted to each peak. This affects mostly the retention time position of the peak.- noise
numeric(1)allowing to set a minimum intensity required for centroids to be considered in the first analysis step (centroids with intensity< noiseare omitted from ROI detection).- verboseColumns
logical(1)whether additional peak meta data columns should be returned.- roiList
An optional list of regions-of-interest (ROI) representing detected mass traces. If ROIs are submitted the first analysis step is omitted and chromatographic peak detection is performed on the submitted ROIs. Each ROI is expected to have the following elements specified:
scmin(start scan index),scmax(end scan index),mzmin(minimum m/z),mzmax(maximum m/z),length(number of scans),intensity(summed intensity). Each ROI should be represented by alistof elements or a single rowdata.frame.- firstBaselineCheck
logical(1). IfTRUEcontinuous data within regions of interest is checked to be above the first baseline. In detail, a first rough estimate of the noise is calculated and peak detection is performed only in regions in which multiple sequential signals are higher than this first estimated baseline/noise level.- roiScales
Optional numeric vector with length equal to
roiListdefining the scale for each region of interest inroiListthat should be used for the centWave-wavelets.- extendLengthMSW
Option to force centWave to use all scales when running centWave rather than truncating with the EIC length. Uses the "open" method to extend the EIC to a integer base-2 length prior to being passed to
convolverather than the default "reflect" method. See https://github.com/sneumann/xcms/issues/445 for more information.- verboseBetaColumns
Option to calculate two additional metrics of peak quality via comparison to an idealized bell curve. Adds
beta_corandbeta_snrto thechromPeaksoutput, corresponding to a Pearson correlation coefficient to a bell curve with several degrees of skew as well as an estimate of signal-to-noise using the residuals from the best-fitting bell curve. See https://github.com/sneumann/xcms/pull/685 and https://doi.org/10.1186/s12859-023-05533-4 for more information.- snthreshIsoROIs
numeric(1)defining the signal to noise ratio cutoff to be used in the second centWave run to identify peaks for predicted isotope ROIs.- maxCharge
integer(1)defining the maximal isotope charge. Isotopes will be defined for charges1:maxCharge.- maxIso
integer(1)defining the number of isotope peaks that should be predicted for each peak identified in the first centWave run.- mzIntervalExtension
logical(1)whether the mz range for the predicted isotope ROIs should be extended to increase detection of low intensity peaks.- polarity
character(1)specifying the polarity of the data. Currently not used, but has to be"positive","negative"or"unknown"if provided.- object
For
findChromPeaks(): anMSnbase::OnDiskMSnExp()object containing the MS- and all other experiment-relevant data.- param
An
CentWavePredIsoParamobject with the settings for the chromatographic peak detection algorithm.- BPPARAM
A parameter class specifying if and how parallel processing should be performed. It defaults to
BiocParallel::bpparam(). See documentation of the BiocParallel package for more details. If parallel processing is enabled, peak detection is performed in parallel on several of the input samples.- return.type
Character specifying what type of object the method should return. Can be either
"XCMSnExp"(default),"list"or"xcmsSet".- msLevel
integer(1)defining the MS level on which the peak detection should be performed. Defaults tomsLevel = 1.- ...
ignored.
Value
The CentWavePredIsoParam() function returns a
CentWavePredIsoParam class instance with all of the settings
specified for the two-step centWave-based peak detection considering also
isotopes.
For findChromPeaks(): if return.type = "XCMSnExp" an
XCMSnExp object with the results of the peak detection.
If return.type = "list" a list of length equal to the number of
samples with matrices specifying the identified peaks.
If return.type = "xcmsSet" an xcmsSet object
with the results of the peak detection.
Details
See centWave() for details on the centWave method.
Parallel processing (one process per sample) is supported and can
be configured either by the BPPARAM parameter or by globally
defining the parallel processing mode using the
BiocParallel::register() method from the BiocParallel
package.
See also
The do_findChromPeaks_centWaveWithPredIsoROIs() core
API function.
XCMSnExp() for the object containing the results of
the peak detection.
Other peak detection methods:
findChromPeaks(),
findChromPeaks-centWave,
findChromPeaks-massifquant,
findChromPeaks-matchedFilter,
findPeaks-MSW
Examples
## Create a param object
p <- CentWavePredIsoParam(maxCharge = 4, snthresh = 25)
p
#> Object of class: CentWavePredIsoParam
#> Parameters:
#> - snthreshIsoROIs: [1] 6.25
#> - maxCharge: [1] 4
#> - maxIso: [1] 5
#> - mzIntervalExtension: [1] TRUE
#> - polarity: [1] "unknown"
#> - ppm: [1] 25
#> - peakwidth: [1] 20 50
#> - snthresh: [1] 25
#> - prefilter: [1] 3 100
#> - mzCenterFun: [1] "wMean"
#> - integrate: [1] 1
#> - mzdiff: [1] -0.001
#> - fitgauss: [1] FALSE
#> - noise: [1] 0
#> - verboseColumns: [1] FALSE
#> - roiList: list()
#> - firstBaselineCheck: [1] TRUE
#> - roiScales: numeric(0)
#> - extendLengthMSW: [1] FALSE
#> - verboseBetaColumns: [1] FALSE